Northstar Fire Sprinkler Design Free Estimate

Design • Stamping • Consulting

Accurate, code-compliant fire sprinkler design, on time.

Northstar Fire Sprinkler Design is a design firm based in Colorado and Alabama, serving clients nationwide, led by a NICET Level III designer with 20 years of experience. We deliver 3D coordinated models (Revit & Navisworks) and clear, professional details. We also provide NICET III and PE stamped plan review, hydrant flow testing, fire protection, and life safety drawings, building plans, and specifications for architects and engineers.

3D riser assembly detail by Northstar
20years designing
867+submittals completed
41stories, tallest building
$3.25Mlargest sprinkler project

Services

New construction, tenant finish and residential, designed to the NFPA standards below.

NFPA 13 Sprinkler systemsNFPA 13R Low-rise residentialNFPA 13D One- & two-family homesNFPA 14 StandpipesNFPA 20 Fire pumpsNFPA 33 Spray booths

Fire Sprinkler Submittals

  • Fire sprinkler shop drawings
  • Hydraulic calculations
  • Equipment submittals
  • Stocklists
  • Seismic bracing calculations (when needed)
  • 3D BIM coordination in Revit & Navisworks: clash detection and coordination with the other trades

Plan Review & Stamps

  • NICET III stamped plan review
  • PE stamped plan review (AL, AZ, CA, CO, TN & TX)
  • Same-day stamps

PE Services for Architects, Engineers & Owners

Need fire protection on your building plans? Our Professional Engineer (PE) services give architects, engineers and owners the fire protection design documents they need, from early schematics through permit, licensed in AL, AZ, CA, CO, TN & TX.

  • Life safety / fire protection drawings and specifications for building permit sets
  • Schematic and design development drawings
  • Fire protection specifications
  • Code consulting and code analysis
  • PE plan review and stamping
  • Water supply and hydraulic evaluations

Contact us with your project, its location and what you need.

Red fire hydrant flowing water through a diffuser with a pressure gauge during a hydrant flow test

Fire Flow Testing (Colorado, North Alabama & Tennessee)

Hydrant flow testing to verify water pressure and flow rates for fire sprinkler design, hydrant performance and code compliance. With a dedicated team available to schedule and perform these tests, we make sure this critical step is completed quickly, reliably and with the precision your project demands.

Contact us with your project, its location and what you need.

Fire Protection License Assistance (RME / NICET III Qualifier)

Need a license holder? We offer fire protection license support, whether you need coverage in your home state, are expanding into new states, or are replacing a current license holder. Our qualified team can sit for state exams, or already holds the NICET certifications and agreements you may need, including acting as your Responsible Managing Employee (RME) or NICET Level III qualifier.

Contact us with your project, its location and what you need.

NICET III & PE Stamped Plan Review — Same-Day Stamps

Our Work

A few details and plans from recent submittals. Tap any image to see it larger.

Notable Projects Designed

  • National Western Stock Show Headquarters, Denver, CO
  • Colorado Rockies McGregor Square, Denver, CO
  • Colorado Rockies Hall of Fame, Denver, CO
  • Denver Fire Station No. 40, Denver, CO
  • Englewood Station, Englewood, CO
  • Inverness Station, Inverness, CO
  • Fort Stewart Courthouse, GA
  • University of Houston Parking Garage, TX
  • Buckley Air Force Base Transfer Facility, CO
  • EAB Brigade Headquarters, Fort Carson, CO
  • Natrona County Juvenile Detention Center, WY
  • Commuter Rail Maintenance Facility, CO

Where We've Worked

AlabamaArizonaCaliforniaColoradoFloridaGeorgiaHawaiiMississippiMissouriMontanaNevadaTennesseeTexasWyomingUS Army Corps of EngineersFactory Mutual

Software

AutoSPRINK PlatinumHydraCAD & HydraLISTAutoCADRevitNavisworksBluebeamAdobe Acrobat ProMicrosoft Office

Avery Schmuck

About Avery

Avery Schmuck is the designer behind Northstar Fire Sprinkler Design. Avery is NICET Level III certified in water-based systems layout and has spent 20 years designing fire sprinkler systems across the country, completing more than 867 submittals for contractors on commercial, industrial, government, multi-family and residential projects.

Before starting Northstar Fire Sprinkler Design, Avery spent years as a designer and senior project manager working for multiple different Colorado fire sprinkler protection contractors, running several high-rise projects at a time and training other designers. Avery's drawings are complete, on deadline and regularly approved by the AHJ on the first submittal.

Let's Talk About Your Project

Send over your drawings and we'll get back to you with a free design estimate.

Request a Free Design Estimate